 FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
December 2006
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Features
User Configurable to 9, 10, 11 or 12-bit Resolution Precision Calibrated to 1C, 0C to 100C
tm
Description
The FM75 contains a high-precision CMOS temperature sensor, a Delta-Sigma analog-to-digital converter, and a SMBus-compatible serial digital interface. Typical accuracy is 2C over the full temperature range of 40C to 125C and to 1C over the range of 0C to 100C, with 9- to 12-bit resolution (default is 9). Thermal alarm output, over-limit signal (OS) supports interrupt and comparator modes. OS is active if the userprogrammable trip-temperature is exceeded. When the temperature falls below the trip temperature, plus the user-programmable hysteresis limit, the OS is disabled. Available in a surface mount SOIC-8 (SOP-8) package.
Typical
Temperature Range: -40C to 125C Low Operating Current (less than 250A) Low Self Heating (0.2C max. in still air) Operating Voltage Range: 2.7V to 5.5V
Applications
Battery Management FAX Management Printers Portable Medical Instruments HVAC Systems Power Supply Modules Disk Drives Computers Automotive Components
Application Diagram
2.7 to 5.5V
8
A0
User Programmable Address
7 6 5
A1 A2
FM75
8-Pin Configuration
3
OS
SMBus Interface
SDA SCL
1 2
4
Figure 1. Typical Application Diagram
Ordering Information
Part Number
FM75M8x
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
Package
8-Lead SOIC
Temperature Range
-40C to +125C
Packing Method
2500 Units, Tape and Reel
www.fairchildsemi.com
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Pin Assignments
SDA SCL OS GND
1 8
VDD A0 A1 A2
2
7
FM75
3 6 4 5
Figure 2. Pin Assignments
Pin Descriptions
Pin #
1 2 3
Name
SDA SCL OS
Direction
Input/Output Input Output
Description
Serial Data. Open drain to I/O-data pin for two-wire interface. Serial Clock. Clock for two-wire serial interface. Over-Limit Signal. Open drain thermostat output that indicates if the temperature exceeds user-programmable limits. Default is active LOW. Ground Address Least Significant Bits (LSBs). User selectable address pins for the three LSBs of the serial interface address. Supply Voltage
4 5, 6, 7 8
GND A0, A1, A2 VDD
Supply Input Supply
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 2
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Absolute Maximum Ratings
The "Absolute Maximum Ratings" are those values beyond which the safety of the device cannot be guaranteed. The device should not be operated at these limits. The parametric values defined in the Electrical Characteristics tables are not guaranteed at the absolute maximum ratings. The "Recommended Operating Conditions" table defines the conditions for actual device operation.
Parameter
Supply Voltage Output Voltage Output Current Storage Temperature Range Lead Soldering Temperature ESD(1) Human Body Model Machine Model
Min.
Typ.
Max.
+7 VCC + 0.5 10
Units
V V mA C C V V
-60
+150 220 2000 250
Note: 1. Human Body Model: 100pF capacitor discharged through a 1.5k resistor into each pin. Machine Model: 200pF capacitor discharged directly into each pin.
Electrical Characteristics(2)
-40C TA +125C, VCC = 5.0V unless otherwise noted. Specifications are subject to change without notice.
Symbol
TMIN, TMAX
Parameter
Specified Temperature Range Temperature Conversion Time Accuracy
(4) (3)
Conditions
Min.
-40
Typ.
90
Max.
+125 +2 +3 +4 +4
Units
C ms
TA = +25C TA = +100C TA = -40C (TMIN) TA = +125C (TMAX)
-2 -3 -4 -4
C
Notes: 2. These specifications are guaranteed only for the test conditions listed. 3. This specification only indicates how often temperature information is updated to the temperature register. The FM75 can be read at any time without interrupting the temperature conversion process. 4. Accuracy (expressed in C) = the difference between the FM75 output temperature and the measured temperature.
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 3
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Logic Electrical Characteristics
Symbol
VIH VIL VOL IDD IDD-SD IIN IOL ILEAK tF CIN
Parameter
Minimum Input Voltage Logic HIGH Maximum Input Voltage Logic LOW Maximum Output Voltage Logic LOW Quiescent Supply Current Shutdown Current Input Leakage Current Output Sink Current Output Leakage Current Output Transition Time Input Capacitance
Conditions
Min.
VDD x 0.7 -0.3
Typ.
Max.
VDD + 0.5 VDD x 0.3 0.36 0.36
Units
V V V V A A A mA A ns pF
VDD = 5V, IOL = -3mA VDD = 3V, IOL = -1.5mA Interface Inactive R/W Activity on SDA Interface Inactive R/W Activity on SDA VIN = 0V or 5V, TA = 25C -40C < TA < 125C TA = 25C, VOL = 0.4V VOH = 5V, VDD = 0V CL = 400pF, IOL = -3mA All Digital Inputs 0.001 250 350 0.15 83
500 700 1 150 0.1 1.0 3 5 250 20
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 4
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Serial Port Timing
Symbol
tSCL tT:LH, tT:HL tLOW tHIGH tBUF tSU:DAT tHD:DAT tHD tSU:STA tHD:STA tSU:STO tPOR
Parameter
SCL Clock Period SCL Clock Transition Time SCL Clock LOW Period SCL Clock HIGH Period Bus free time between a Stop and a new Start Condition Data In Set-up to SCL HIGH Data In Hold Time Data Out Stable after SCL LOW SCL LOW Set-up to SDA LOW (Repeated Start Condition) SCL HIGH Hold after SDA LOW (Start Condition) SDA HIGH after SCL HIGH (Stop Condition) Time in which a FM75 must be operational after a power-on reset
Conditions
Min.
1.0 0.470 0.400 1.0 100 100 0 100 100 100
Typ.
Max.
100 300 50
Units
s ns s s s ns ns ns ns ns ns
500
ms
tSCL
SCL
tHD:STA tSU:DAT
tSU:STA tSU:STO
SDA Data In
tBUF tHD:DAT
tLOW
tHIGH
tT:LH 90% 10%
tT:HL
SCL
90% 10%
SDA Data Out
tHD
Figure 3. Serial Port Timing Diagram
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 5
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Basic Operation
The FM75 temperature sensing circuitry continuously produces analog voltage proportional to the device temperature. At regular intervals, the FM75 converts the analog voltage to a two's complement digital value, which is placed into the temperature register. The FM75 has an SMBus-compatible digital serial interface that allows access to the data in the temperature register at any time. In addition, the serial interface provides access to all other FM75 registers to customize operation of the device. The FM75 temperature-to-digital conversion can have 9, 10, 11, or 12-bit resolution selected, providing 0.5C, 0.25C, 0.125C, and 0.0625C temperature resolution, respectively. At power-up, the default conversion resolution is 9-bits. The conversion resolution is controlled by the R0 and R1 bits in the configuration register. Table 1 gives examples of the relationship between the output digital data and the external temperature. The 9-bit, 10-bit, 11-bit, and 12-bit columns in Table 1 indicate the right-most bit in the output data stream that can contain temperature information for each conversion accuracy. Since the output digital data is in two's-complement format, the most significant bit of the temperature is the "sign" bit. If the sign bit is zero, the temperature is positive; if the sign bit is one, the temperature is negative. The FM75 has a shutdown mode that reduces the operating current to 150nA. This mode is controlled by the SD bit in the configuration register.
All Temperatures
Table 1. Relationship Between Temperature and Digital Output
Temperature Digital Output
Number of bits used by conversion resolution
Sig
bi t 9
bit 10
bit 11
bit 12
Always zero
12-Bit Resolution 11 -Bit Resolution 10 -Bit Resolution 9-Bit Resolution +125 C +100.0625 C +50.125 C +12.25 C 0C -20.5 C -33.25C -45.0625 C -55C 0 0 0 0 0 1 1 1 1 111 110 011 000 000 110 101 101 100 1101 0100 0010 1100 0000 1011 1110 0010 1001 0 0 0 0 0 1 1 1 0 0 0 0 0 1 0 0 1 1 0 0 0 0 0 1 0 0 0 0 1 0 0 0 0 0 1 0 0 0 0 0 1 0
0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000 0000
Power-Up Default Conditions
The FM75 powers up in the following default state: * Thermostat mode: comparator mode * OS polarity: active LOW * Fault tolerance: 1 fault (i.e., F0 = 0 and F1 = 0 in the configuration register) * TOS: 80C * THYST: 75C * Register pointer: 00 (temperature register) * Conversion resolution: 9 bits (i.e., R0 = 0 and R1 = 0 in the configuration register) After power-up, these conditions can be reprogrammed via the serial interface. Refer to the Serial Data Bus Operation section for FM75 programming instructions. The OS polarity is controlled by the POL bit in the configuration register. The programmable upper trip-point temperature for the thermal alarm is stored in the TOS register. The programmable hysteresis temperature (i.e., the lower trip point) is stored in the THYST register. The thermal alarm has two modes of operation: comparator mode and interrupt mode. At power-up, the default is comparator mode. The alarm mode is controlled by the CMP/INTR bit in the configuration register.
Fault Tolerance
For both comparator and Interrupt modes, the alarm "fault tolerance" setting plays a role in determining when the OS output is activated. Fault tolerance refers to the number of consecutive times an error condition must be detected before the user is notified. Higher fault tolerance settings can help eliminate false alarms caused by noise in the system. The alarm fault tolerance is controlled by bits F0 and F1 in the configuration register. These bits can be used to set the fault tolerance to 1, 2, 4, or 6, as shown in Table 4. At power-up, these bits both default to 0 (fault tolerance = 1).
Thermal Alarm Function
The FM75 thermal alarm function provides programmable thermostat capability and allows the FM75 to function as a stand-alone thermostat without using the serial interface. The Over-Limit Signal (OS) output is the alarm output. This signal is an open-drain output and, at power-up, this pin is configured with active-low polarity.
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 6
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Comparator Mode
In comparator mode, each time a temperature-to-digital (T-to-D) temperature conversion occurs, the new digital temperature is compared to the value stored in the TOS and THYST registers. If a fault tolerance number of consecutive temperature measurements are greater than the value stored in the TOS register, the OS output is activated. For example, if bits F1 and F0 are equal to "10" (fault tolerance = 4), four consecutive temperature measurements must exceed TOS to activate the OS output. Once the OS output is active, it remains active until the first time the measured temperature drops below the temperature stored in the THYST register. The operation of the alarm in comparator mode with fault tolerance = 2 is illustrated in Figure 4.
Interrupt Mode
In interrupt mode, the OS output first becomes active after a fault tolerance number of consecutive temperature measurements exceed the value stored in the TOS register (similar to comparator mode). Once OS is active, it can only be cleared by a user read from any of the FM75 registers (temperature, configuration, TOS, or THYST) or by putting the FM75 into shutdown mode (i.e., by setting the shutdown bit in the configuration register to "1"). Once cleared, the OS output can only be activated the next time by a fault tolerance number of consecutive temperature measurements lower than the value stored in THYST. Once it is activated, the OS output can only be deactivated by a user read or shutdown. In interrupt mode, the activate/clear cycle for OS has the following pattern: temperature > TOS, clear, temperature < THYST, clear, temperature > TOS, clear, etc. The operation of the alarm in interrupt mode with fault tolerance = 2 is illustrated in Figure 4.
Temperature-to-Digital Conversion
TOS
THYST
OS (Comparator Mode)
OS (Interrupt Mode)
For this example: Fault Tolerance = 2 Output Polarity = Active Low
Read (or Shutdown)
Figure 4. Thermal Alarm Operation in Comparator and Interrupt Modes
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 7
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Registers
The FM75 contains the following five registers:
Command Register Temperature Register Configuration Register Over-Limit-Signal Temperature Register (TOS) Hysteresis Temperature Register (THYST)
All of these registers can be accessed by the user via the digital serial interface at any time (see Serial Interface Operation for instructions). A detailed description of these registers and their functions is provided in the following sections. A diagram of the register hierarchy is shown in Figure 5.
SD A
SCL Temperature Register
Serial Interface
Read/Write Data
2-byte Read Only Command Reg. = 00000000
Configuration Register
Command (P ointer ) Data 1-byte Read/Write Command Reg. = 00000001
THYST Register 2-byte Read/Write Command Reg. = 00000010 Command Register
1-byte Write Only
TOS Register 2-byte Read/Write Command Reg. = 00000011
Figure 5. Register Hierarchy
Command Register
The command register is a one-byte (8-bit) write-only register. The data stored in the command register indicates which of the other registers (temperature, configuration, TOS, or THYST) to read from or write to during an upcoming operation. The command register "points" to the selected register, as shown in Figure 11. The command register is illustrated in Figure 9. The P1 and P0 bits of the command register determine which register is accessed, as shown in Table 2. The six Most Significant Bits (MSBs) of the command register must always be zero. Writing a one into any of these bits causes the current operation to be terminated. The command register retains pointer information between operations; therefore, this register only needs to be updated once for consecutive read operations from the same register. All bits in the command register default to zero at power-up.
MSB
LSB
0
0
0
0
0
0 P1 P0
Figure 6. Command Register Format
Table 2. Register Assignments for Command Bits P1 and P2
Register
Temperature Register Configuration Register THYST Register TOS Register
P1
0 0 1 1
P0
0 1 0 1
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 8
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Temperature Register
The temperature register is a two-byte (16-bit) read-only register. Digital temperatures from the T-to-D converter are stored in the temperature register in two's complement format and the contents of this register are updated at regular intervals, each time the T-to-D conversion is finished. The user can read data from the temperature register at any time. When a T-to-D conversion is completed, the new data is loaded into a comparator buffer to evaluate fault conditions and updates the temperature register if a read cycle is not ongoing. The FM75 is continuously evaluating fault conditions regardless of read or write activity on the bus. If a read is ongoing, the previous temperature is read. The readable temperature is updated upon the completion of the next T-to-D conversion not masked by a read cycle. The temperature register is illustrated in Figure 7. Depending on the resolution of the T-to-D conversion, the 9, 10, 11, or 12 MSBs of the register contain temperature data. All unused bits following the digital temperature are zero. The MSB position of the temperature register always contains the sign bit for the digital temperature and bit 14 contains the temperature MSB. Bits in the temperature register default to zero at power-up.
Configuration Register
The configuration register is a one-byte (8-bit) read/write register (see Figure 8). This register allows the user to control the FM75 shutdown mode as well as the following thermal alarm features: polarity, operating mode, and fault tolerance. The configuration register contains two bits that set the fault tolerance trip point. The fault tolerance trip point is the number of consecutive times the internal circuit reads the temperature and finds the temperature outside the limits programmed. The programmed limits are defined by the TOS register for the upper limit and by the THYST register for the lower limit. Table 4 shows the relationship between F1 and F0 and the number of consecutive errors or "trips" needed to activate the alarm. The configuration register also contains the two bits that set the T-to-D conversion resolution to 9, 10, 11, or 12 bits. Table 3 shows the relationship between R1 and T0 and the conversion resolution. All bits in the configuration register default to zero at power-up.
MSB
6
5
4
3
2
1
LSB
X R1 R0 F1 F0 POL CMP/ SD INT
R1 = Resolution bit 1 (see Table 3). R0 = Resolution bit 0 (see Table 3). F1 = Fault tolerance bit 1 (see Table 4). F0 = Fault tolerance bit 0 (see Table 4). POL = OS output polarity: 0 = active low, 1 = active high. CMP/INT = thermostat mode: 0 = comparator mode, 1 = inerrupt mode. SD = shutdown: 0 = normal operation, 1 = shutdown mode. Figure 8. Configuration Register Format
MSB 14
13
12
11
10
9
8
SB
TMSB
T
T
T
T
T
T
7
9-bit LSB
6
10-bit LSB
5
11-bit LSB
4
12-bit LSB
3
2
1
LSB
0
0
0
0
SB = Two's complement sign bit TMSB = Temperature MSB T = Temperature data 9-bit LSB = Temperature LSB for 9-bit conversions 10-bit LSB = Temperature LSB for 10-bit conversions 11-bit LSB = Temperature LSB for 11-bit conversions 12-bit LSB = Temperature LSB for 12-bit conversions Figure 7. Temperature Register Format
Table 3. Conversion Resolution Settings A-to-D Conversion Resolution
9 Bits 10 Bits 11 Bits 12 Bits
R1
0 0 1 1
R0
0 1 0 1
Table 4. Fault Tolerance Settings Fault Tolerance
1 2 4 6
R1
0 0 1 1
R0
0 1 0 1
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 9
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Over-Limit Signal Temperature Register (TOS)
The TOS register is a two-byte (16-bit) read/write register that stores the user-programmable upper trip-point temperature for the thermal alarm in two's-complement format. At power-up, this register defaults to 80C (i.e. 0101 0000 0000 0000). The format of the TOS register is identical to that of the temperature register (see Figure 9). The four LSBs of the TOS register are hardwired to zero, so data written to these register bits is ignored. The MSB position of the TOS register contains the sign bit for the digital temperature and bit 14 contains the temperature MSB. The resolution setting for the T-to-D conversion determines how many bits of the TOS register are used by the thermal alarm. For example, for 9-bit conversions, the trip-point temperature is defined by the nine MSBs of the TOS register and all remaining bits are ignored.
Hysteresis Temperature Register (THYST)
The THYST register is a two-byte (16-bit) read/write register that stores the programmable lower trip-point temperature for the thermal alarm in two's-complement format. At power-up, this register defaults to 75C (i.e. 0100 1011 0000 0000). The THYST register is illustrated in Figure 9. The format of this register is the same as that of the temperature register. The four LSBs of the THYST register are hardwired to zero, so data written to these bits is ignored. The resolution setting for the T-to-D conversion determines how many bits of the THYST register are used by the thermal alarm. For example, for 9-bit conversions, the hysteresis temperature is defined by the nine MSBs of the THYST register and all remaining bits are ignored. .
MSB 14
13
12
11
10
9
8
SB
TMSB
T
6
10-bit LSB
T
5
11-bit LSB
T
4
12-bit LSB
T
3
T
2
T
1 LSB
7
9-bit LSB
0
0
0
0
SB = Two's complement sign bit TMSB = Temperature MSB T = Temperature data 9-bit LSB = Temperature LSB for 9-bit conversions 10-bit LSB = Temperature LSB for 10-bit conversions 11-bit LSB = Temperature LSB for 11-bit conversions 12-bit LSB = Temperature LSB for 12-bit conversions Figure 9. THYST Register and TOS Register Format
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 10
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Serial Data Bus Operation
General Operation
Writing to and reading from the FM75 registers is accomplished via the SMBus-compatible two-wire serial interface. SMBus protocol requires that one device on the bus initiates and controls all read and write operations. This device is called the "master" device. The master device also generates the SCL signal, which is the clock signal for all other devices on the bus. All other devices on the bus are called "slave" devices. The FM75 is a slave device. Both the master and slave devices can send and receive data on the bus. During SMBus operations, one data bit is transmitted per clock cycle. All SMBus operations follow a repeating nine clock-cycle pattern that consists of eight bits (one byte) of transmitted data followed by an acknowledge (ACK) or not acknowledge (NACK) from the receiving device. Note that there are no unused clock cycles during any operation--therefore there must be no breaks in the stream of data and ACKs/NACKs during data transfers. Conversely, too few clock cycles can lead to incorrect operation if an inadvertent 8-bit read from a 16-bit register occurs. For most operations, SMBus protocol requires the SDA line to remain stable (unmoving) whenever SCL is HIGH-- i.e., transitions on the SDA line can only occur when SCL is LOW. The exceptions to this rule are when the master device issues a start or stop signal. The slave device cannot issue a start or stop signal. Start Condition: This condition occurs when the SDA line transitions from HIGH to LOW while SCL is HIGH. The master device uses this condition to indicate that a data transfer is about to begin. Stop Condition: This condition occurs when the SDA line transitions from LOW to HIGH while SCL is HIGH. The master device uses this condition to signal the end of a data transfer. Acknowledge and Not Acknowledge: When data is transferred to the slave device, it sends an acknowledge (ACK) after receiving every byte of data. A master device sends an acknowledge (ACK) following only the first byte read from a two-byte register. The receiving device sends an ACK by pulling SDA LOW for one clock cycle. Following the last byte, a master device sends a "not acknowledge" (NACK) followed by a stop condition. A NACK is indicated by leaving SDA HIGH during the clock after the last byte.
Slave Address
Each slave device on the bus has a unique 7-bit address so the master can identify which device is sending or receiving data. The FM75 address is as follows:
1
0
0
1 A2 A1 A0
The four MSBs of the FM75 address are hardwired to 1001. The three LSBs are user configurable by tying the A0, A1, and A2 pins to either VDD or ground. This provides eight different FM75 addresses, which allows up to eight FM75s to be connected to the same bus.
Writing to and Reading from the FM75
All read and write operations must begin with a start signal generated by the master device. After the start condition, the master device must immediately send a slave address (7 bits), followed by a read/write bit. If the slave address matches the address of the FM75, the FM75 sends an ACK after receiving the read/write bit by pulling the SDA line LOW for one clock cycle. Figures 11 -16 provide timing diagrams for all FM75 operations.
Setting the Pointer
For all operations, the pointer stored in the command register must be pointing to the register (temperature, configuration, TOS or THYST) that is going to be written to or read from. To change the pointer value in the command register, the read/write bit following the address must be 0. This indicates that the master will write new information into the command register. After the FM75 sends an ACK in response to receiving the address and read/write bit, the master device must transmit an appropriate 8-bit pointer value, as explained in the Registers section. The FM75 sends an ACK after receiving the new pointer data. The pointer set operation is illustrated in Figure 11. Anytime a pointer set is performed, it must be immediately followed by a read or write operation. Note that the six MSBs of the pointer value must be zero. If the six MSBs are not zero, the FM75 does not send an ACK and internally terminates the operation. The command register retains the current pointer value between operations; therefore, once a register is indicated, subsequent read operations do not require a pointer set cycle. Write operations always require the pointer be reset.
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 11
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Reading
If the pointer is already pointing to the desired register, the master can read from that register by setting the read/write bit (following the slave address) to a one. After sending an ACK, the FM75 begins transmitting data during the following clock cycle. If the configuration register is being read, the FM75 transmits one byte of data (see Figure 13). The master should respond with a NACK, followed by a stop condition. If the temperature, TOS, or THYST register is being read, the FM75 transmits two bytes of data (see Figure 12). The master must respond to the first byte of data with an ACK and to the second byte of data with a NACK followed by a stop condition. To read from a register other than the one currently indicated by the command register, a pointer to the desired register must be set. Immediately following the pointer set, the master must perform a repeat start condition (see Figure 11 and Figure 15), which indicates to the FM75 that a new operation is about to occur. If the repeat start condition does not occur, the FM75 assumes that a write is taking place and the selected register is overwritten by the upcoming data on the data bus. After the start condition, the master must again send the device address and read/write bit. This time, the read/ write bit must be set to one to indicate a read. The rest of the read cycle is the same as described in the previous paragraph for reading from a preset pointer location.
Writing
All writes must be proceeded by a pointer set, even if the pointer is already pointing to the desired register. Immediately following the pointer set, the master must begin transmitting the data to be written. If the master is writing to the configuration register, one byte of data must be sent (see Figure 16). If the TOS or THYST register is being written, the master must send two bytes of data (see Figure 14). After transmitting each byte of data, the master must release the Serial Data (SDA) line for one clock cycle to allow the FM75 to acknowledge receiving the byte. The write operation should be terminated by a stop signal from the master.
Caution: Inadvertent 8-Bit Read from a 16-Bit Register
An inadvertent 8-bit read from a 16-bit register, with the D7 bit LOW, can cause the FM75 to pause in a state where the SDA line is pulled LOW by the output data and is incapable of receiving either a stop or a start condition from the master. The only way to remove the FM75 from this state is to continue clocking for nine cycles until SDA goes HIGH, at which time issuing a stop condition resets the FM75, shown in Figure 10.
Nine additional clock cycles to reset the FM75 SCL SDA 1 Start from Master 0 0 1 A2 A1 A0 R/W A D7 D6 D5 D4 D3 D2 D1 D0 N Ack from FM75 No Ack from Master D7 D6 D5 D4 D3 D2 D1 D0 N No Ack Stop from Condition from Master Master
Address Byte
Most Significant Data Byte (from FM75)
Stop intended by Master, but FM75 SDA line locked low
Master must detect error condition on FM75
Figure 10. Inadvertent 8-Bit Read from 16-Bit Register Where D7 = 0 and Forces Output LOW
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 12
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Timing Diagrams
Note: This segment of this timing diagram is a generic pointer set cycle that must be followed by either an immediate read cycle or write cycle, as shown in this figure and in figures 10, 11, and 12.
SCL
....
S 1 0 0 1 A2 A1 A0 R/W A 0 0 0 0 0 0 P1 P0 A Ack from aTS75
SDA
....
Address Byte
SCL ... SDA
Ack from FM75
Pointer Byte
...
S
1
0
0
1
A2
A1
A0 R/W
A
D7
D6
D5
D4
D3
D2
D1
D0
A Ack from Master
D7
D6
D5
D4
0
0
0
0
N No Ack from Master
P
Repeat Start from Master
Address Byte
Ack from FM75
Most Significant Data Byte (from FM75)
Least Significant Data Byte (from FM75)
Figure 11. Pointer Set Followed by Immediate Read from a Two-byte Register (Temperature, TOS, or THYST Register)
SCL
SDA
S
1
0
0
1
A2
A1
A0
R/W
A Ack from FM75
D7
D6
D5
D4
D3
D2
D1
D0
A Ack from Master
D7
D6
D5
D4
0
0
0
0
N
P
Address Byte
Most Significant Data Byte (from FM75)
Least Significant Data Byte (from FM75)
No Ack from Master
Figure 12. Two-byte Read from Preset Pointer Location (Temperature, TOS, or THYST Register)
SCL
SDA
S
1
0
0
1
A2
A1
A0
R/W
A
X
D6
D5
D4
D3
D2
D1
D0
N
P
Address Byte
Ack from FM75
Data Byte (from FM75)
No Ack from Master
Figure 13. One-byte Read from Configuration Register with Preset Pointer
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 13
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Timing Diagrams (Continued)
SCL 0 0 0
....
S 1 0 0 1 A2 A1 A0 R/W A 0 0 0 P1 P0 A
SDA
....
Address Byte
Ack from FM75
Pointer Byte
Ack from FM75
.... ....
A D7 D6 D5 D4 D3 D2 D1 D0 A D7 D6 D5 D4 0 0 0 0 A P
Most Significant Data Byte (from Master)
Ack from FM75
Least Significant Data Byte (from Master)
Ack from FM75
Figure 14. Pointer Set Followed by Immediate Write to A 2-byte Register (TOS or THYST Register)
SCL
SDA
S
1
0
0
1
A2
A1
A0
R/W
A
0
0
0
0
0
0
P1
P0
A
S
1
0
0
1
A2
A1
A0
R/W
Address Byte
Ack from FM75
Pointer Byte
Ack from Repeat Start from FM75 Master
Address Byte
.... ....
1 0 0 1 A2 A1 A0 R/W A X D6 D5 D4 D3 D2 D1 D0 N No Ack from Master P
Address Byte (repeated here for clarity, transmitted only once in the actual sequence)
Ack from FM75
Data Byte (from FM75)
Figure 15. Pointer Set Followed by Immediate Read from Configuration Register
SCL S SDA 1 0 0 1 A2 A1 A0 R/W A Ack from FM75 0 0 0 0 0 0 P1 P0 A Ack from FM75 X D6 D5 D4 D3 D2 D1 D0 A Ack from FM75 P
Address Byte
Pointer Byte
Data Byte (from Master)
Figure 16. Pointer Set Followed by Immediate Write to the Configuration Register
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 14
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
Mechanical Dimensions
Dimensions are in inches (millimeters) unless otherwise noted.
Figure 17. Molded Package, Small Outline, 0.15 Wide, 8-Lead (M8)
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 15
FM75 Low-Voltage Two-Wire Digital Temperature Sensor with Thermal Alarm
(c) 2006 Fairchild Semiconductor Corporation FM75 Rev. 1.0.8
www.fairchildsemi.com 16


▲Up To Search▲   

 
Price & Availability of FM7506

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X